Please use this identifier to cite or link to this item: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/2074
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDesai, Sagar J.en_US
dc.contributor.authorBharne, Ashish P.en_US
dc.contributor.authorUpadhya, Manoj A.en_US
dc.contributor.authorSomalwar, Amita R.en_US
dc.contributor.authorSUBHEDAR, NISHIKANT K.en_US
dc.contributor.authorKokare, Dadasaheb M.en_US
dc.date.accessioned2019-02-25T09:04:44Z
dc.date.available2019-02-25T09:04:44Z
dc.date.issued2014-04en_US
dc.identifier.citationJournal of Pharmacological and Toxicological Methods, 69(2), 141-149.en_US
dc.identifier.issn1056-8719en_US
dc.identifier.issn1873-488Xen_US
dc.identifier.urihttp://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/2074-
dc.identifier.urihttps://doi.org/10.1016/j.vascn.2013.12.006en_US
dc.description.abstractntracranial self-stimulation (ICSS) is an operant paradigm in which rodents self-administer rewarding electrical stimulation through electrodes implanted into the brain. We describe a simple, inexpensive and reliable method to fabricate monopolar and bipolar electrodes, along with the swivel system, for delivery of electric pulses at the targeted sites in the brain of rat. Methods The system consists of an insulated stainless steel wire(s) (diameter: 0.25 mm), plastic base, pedestal and connector attached to a swivel via a stimulating cable, which is connected to the stimulator. We provide the specifications, source of each component, and the method of fabrication in details. Results In-house fabricated monopolar or bipolar electrodes were subjected to rigorous tests. We implanted the electrode into the medial forebrain bundle (MFB) and rat was trained to press the lever for electrical self-stimulation in operant chamber for 60 min each day. In about 3–4 days, the animal gave a consistent response (~ 40 presses/min) and was considered as conditioned. For evaluation of reinforcement behavior, the number of lever pressings of conditioned rat with or without electrical stimulation was assessed for a period of 30 min each day for 10 weeks. The rewarding frequency sustained for the entire duration. In addition, we compared the lever pressing data of the groups of rats implanted with in-house fabricated versus with those with commercial electrodes; no significant differences were encountered. Discussion The required components for the electrode fabrication are easily available. With some practice, the system can be easily assembled in the laboratory and costs less than a dollar. We suggest that the electrodes, fabricated using this method, may serve as an economical and reliable tool in neuropharmacological and neurobehavioral studies.en_US
dc.language.isoenen_US
dc.publisherElsevier B.V.en_US
dc.subjectEconomical methoden_US
dc.subjectElectrode fabricationen_US
dc.subjectBrain self-stimulation in ratsen_US
dc.subjectIntracranial self-stimulation|ICSSen_US
dc.subjectBipolar electrodesen_US
dc.subjectOperant conditioningen_US
dc.subjectRatsen_US
dc.subject2014en_US
dc.titleA simple and economical method of electrode fabrication for brain self-stimulation in ratsen_US
dc.typeArticleen_US
dc.contributor.departmentDept. of Biologyen_US
dc.identifier.sourcetitleJournal of Pharmacological and Toxicological Methodsen_US
dc.publication.originofpublisherForeignen_US
Appears in Collections:JOURNAL ARTICLES

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.