Title: Mechanical stability of the CMS strip tracker measured with a laser alignment system
Authors: CMS Collaboration
Sirunyan, A. M.
CHAUHAN, S.
DUBE, SOURABH
HEGDE, V.
KAPOOR, A.
KOTHEKAR, K.
PANDEY, S.
RANE, A.
SHARMA, SEEMA et al.
Dept. of Physics
Keywords: CMS tracker consists
Silicon strip
Carbon fibre composite
Operation in the temperature
Initial positions
2017
Issue Date: Apr-2017
Publisher: IOP Publishing
Citation: Journal of Instrumentation, 12,P04023.
Abstract: The CMS tracker consists of 206 m2 of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from −25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements of tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value.
URI: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/3589
https://doi.org/10.1088/1748-0221/12/04/P04023
ISSN: 1748-0221
Appears in Collections:JOURNAL ARTICLES

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.