Please use this identifier to cite or link to this item: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/4722
Title: Response of CMS High Granularity Calorimeter Prototype to Charged Pions
Authors: SHARMA, SEEMA
GOGATE, NIRAMAY
Dept. of Physics
20151101
Keywords: CMS
HGCAL
Calorimetry
2020
Issue Date: Apr-2020
Abstract: This thesis presents the calibration and performance study of CMS High Granularity Calorimeter (HGCAL) based on the data collected during the beam tests conducted in 2018. The muon run data was used to calibrate the silicon sensors of HGCAL which record the energy deposits of the incoming high energy particles. The calibration values thus found were then used to study the signal-to-noise ratio of these sensors. The pion run data was later used to check the energy response and resolution of the detector. The simulation of the passage of charged pions through HGCAL test-beam setup was used to understand the leakage and absorbed energy profile. With multiple active layers available, the shower start algorithm was used to predict the approximate location of the first hadronic interaction of the pion with the detector material. In order to improve the pion energy resolution, a simple machine learning regression model was considered which gave better results than the conventional methods, suggesting the possibility for improvement with more complex machine learning models.
URI: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/4722
Appears in Collections:MS THESES

Files in This Item:
File Description SizeFormat 
Niramay_Final_Corrected.pdfMS Thesis3.32 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.