Please use this identifier to cite or link to this item: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/4895
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCMS Collaborationen_US
dc.contributor.authorSirunyan, A. M.en_US
dc.contributor.authorCHAUHAN, S.en_US
dc.contributor.authorDUBE, SOURABHen_US
dc.contributor.authorHEGDE, V.en_US
dc.contributor.authorKANSAL, B.en_US
dc.contributor.authorKAPOOR, A.en_US
dc.contributor.authorKOTHEKAR, K.en_US
dc.contributor.authorPANDEY, S.en_US
dc.contributor.authorRANE, A.en_US
dc.contributor.authorRASTOGI, A.en_US
dc.contributor.authorSHARMA, SEEMA et al.en_US
dc.date.accessioned2020-07-24T05:59:04Z
dc.date.available2020-07-24T05:59:04Z
dc.date.issued2020-06en_US
dc.identifier.citationJournal of Instrumentation, 15(6).en_US
dc.identifier.issn1748-0221en_US
dc.identifier.urihttp://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/4895-
dc.identifier.urihttps://doi.org/10.1088/1748-0221/15/06/P06009en_US
dc.description.abstractMeasurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.en_US
dc.language.isoenen_US
dc.publisherIOP Publishingen_US
dc.subjectCMSen_US
dc.subjectPhysicsen_US
dc.subjectTOC-JUL-2020en_US
dc.subject2020en_US
dc.subject2020-JUL-WEEK4en_US
dc.titleMeasurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeteren_US
dc.typeArticleen_US
dc.contributor.departmentDept. of Physicsen_US
dc.identifier.sourcetitleJournal of Instrumentationen_US
dc.publication.originofpublisherForeignen_US
Appears in Collections:JOURNAL ARTICLES

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.