Title: | Compton polarimeter as a focal plane detector for hard X-ray telescope: sensitivity estimation with Geant4 simulations |
Authors: | Chattopadhyay, T. Vadawale, S. V. PENDHARKAR, J. Dept. of Physics |
Keywords: | Hard X-ray polarimetry X-ray instrumentation Compton polarimetry X-ray detectors 2013 |
Issue Date: | Apr-2013 |
Publisher: | Springer Nature |
Citation: | Experimental Astronomy, 35(3), 391-412. |
Abstract: | X-ray polarimetry can be an important tool for investigating various physical processes as well as their geometries at the celestial X-ray sources. However, X-ray polarimetry has not progressed much compared to the spectroscopy, timing and imaging mainly due to the extremely photon-hungry nature of X-ray polarimetry leading to severely limited sensitivity of X-ray polarimeters. The great improvement in sensitivity in spectroscopy and imaging was possible due to focusing X-ray optics which is effective only at the soft X-ray energy range. Similar improvement in sensitivity of polarisation measurement at soft X-ray range is expected in near future with the advent of GEM based photoelectric polarimeters. However, at energies >10 keV, even spectroscopic and imaging sensitivities of X-ray detector are limited due to lack of focusing optics. Thus hard X-ray polarimetry so far has been largely unexplored area. On the other hand, typically the polarisation degree is expected to increase at higher energies as the radiation from non-thermal processes is dominant fraction. So polarisation measurement in hard X-ray can yield significant insights into such processes. With the recent availability of hard X-ray optics (e.g. with upcoming NuSTAR, Astro-H missions) which can focus X-rays from 5 KeV to 80 KeV, sensitivity of X-ray detectors in hard X-ray range is expected to improve significantly. In this context we explore feasibility of a focal plane hard X-ray polarimeter based on Compton scattering having a thin plastic scatterer surrounded by cylindrical array scintillator detectors. We have carried out detailed Geant4 simulation to estimate the modulation factor for 100 % polarized beam as well as polarimetric efficiency of this configuration. We have also validated these results with a semi-analytical approach. Here we present the initial results of polarisation sensitivities of such focal plane Compton polarimeter coupled with the reflection efficiency of present era hard X-ray optics. |
URI: | http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5199 https://doi.org/10.1007/s10686-012-9312-3 |
ISSN: | 0922-6435 1572-9508 |