Please use this identifier to cite or link to this item: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5713
Title: Synthesis of highly sensitive rGO@CNT@Fe2O3/polypyrrole nanocomposite for the electrochemical detection of Pb2+
Authors: FALL, BALLA
Diaw, Abdou K.D.
Fall, Modou
Sall, Mohamed L.
Lo, Momath
Gningue-Sall, Diariatou
THOTIYL, MUSTHAFA OTTAKAM
Maria, Hanna J.
Kalarikkal, Nandakumar
homas, Sabu
Dept. of Chemistry
Keywords: Polypyrrole
Reduced graphene oxide
Carbon nanotubes
Iron oxide
2021-MAR-WEEK2
TOC-MAR-2021
2021
Nanocomposites
Lead ions
Square Wave Anodic Stripping Voltammetry
Issue Date: Mar-2021
Publisher: Elsevier B.V.
Citation: Materials Today Communications, 26, 102005.
Abstract: In this work, highly sensitive nanocomposite materials for the recognition of lead ions in aqueous medium are developed by combining reduced graphene oxide (rGO), carbon nanotubes (CNT) and iron oxide (Fe2O3) drop-casted (as a composite) on a glassy carbon electrode (GCE). This modified electrode was used as a scaffold for polypyrrole (PPy) electrosynthesis, which leaded to the design of a new advanced functional conductive polymeric material (rGO@CNT@Fe2O3/PPy). The physicochemical properties of the composite were probed by X-ray diffraction (XRD), Raman spectroscopy, Fourier-Transform Infra-Red spectroscopy (FTIR) and Scanning Electron Microscopy. The rGO@CNT@Fe2O3/PPy films generated by this strategy exhibited excellent stability and superior conductivity than bare PPy modified surface (without rGO + CNT + Fe2O3 composite). The optimized rGO@CNT@Fe2O3/PPy electrode was applied to the detection of Pb2+ (deposition potential of -1.3 V vs. Ag/AgCl), with peak potential of -0.6 V vs. Ag/AgCl and a higher stripping current peak (1.5 μA/cm2) compared to GCE, rGO@CNT/GCE and rGO@CNT@Fe2O3/GCE. The calibration curve is linear in the range from 0.02 to 0.26 μM (R2 = 0.992), with a sensitivity of 162.8 μA°μM−1 and a detection limit (LOD) of 0.1 nM. Moreover, the modified electrode exhibited low metallic interference, high repeatability and good reproducibility towards the detection of Pb2+. Finally, the usefulness of the nanocomposite was realized by the determination of Pb2+ in tap water.
URI: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5713
https://doi.org/10.1016/j.mtcomm.2020.102005
ISSN: 2352-4928
Appears in Collections:JOURNAL ARTICLES

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.