Please use this identifier to cite or link to this item:
http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5752
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | CMS Collaboration | en_US |
dc.contributor.author | Khachatryan,V | en_US |
dc.contributor.author | DUBE, SOURABH | en_US |
dc.contributor.author | KANSAL, B. | en_US |
dc.contributor.author | KAPOOR, A. | en_US |
dc.contributor.author | KOTHEKAR, K. | en_US |
dc.contributor.author | PANDEY, S. | en_US |
dc.contributor.author | RANE, A. | en_US |
dc.contributor.author | RASTOGI, A. | en_US |
dc.contributor.author | SHARMA, SEEMA et al. | en_US |
dc.date.accessioned | 2021-03-30T09:17:14Z | |
dc.date.available | 2021-03-30T09:17:14Z | |
dc.date.issued | 2021-02 | en_US |
dc.identifier.citation | Journal of Instrumentation, 16, P02010. | en_US |
dc.identifier.issn | 1748-0221 | en_US |
dc.identifier.uri | http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5752 | |
dc.identifier.uri | https://doi.org/10.1088/1748-0221/16/02/P02010 | en_US |
dc.description.abstract | The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1cm from the beam pipe, and at 14.4m from the CMS interaction point, covering the pseudorapidity range of −6.6 < η < −5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IOP Publishing | en_US |
dc.subject | Calorimeters | en_US |
dc.subject | Cherenkov detectors | en_US |
dc.subject | Large detector systems for particle and astroparticle physics | en_US |
dc.subject | 2021-MAR-WEEK4 | en_US |
dc.subject | TOC-MAR-2021 | en_US |
dc.subject | 2021 | en_US |
dc.title | The very forward CASTOR calorimeter of the CMS experiment | en_US |
dc.type | Article | en_US |
dc.contributor.department | Dept. of Physics | en_US |
dc.identifier.sourcetitle | Journal of Instrumentation | en_US |
dc.publication.originofpublisher | Foreign | en_US |
Appears in Collections: | JOURNAL ARTICLES |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.