Please use this identifier to cite or link to this item: http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/6336
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSINGH, MOHIT KUMARen_US
dc.contributor.authorDATTA, SHOUVIKen_US
dc.date.accessioned2021-11-01T04:13:55Z
dc.date.available2021-11-01T04:13:55Z
dc.date.issued2021-10en_US
dc.identifier.citationReview of Scientific Instruments, 92(10), 105109.en_US
dc.identifier.issn0034-6748en_US
dc.identifier.issn1089-7623en_US
dc.identifier.urihttp://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/6336
dc.identifier.urihttps://doi.org/10.1063/5.0041438en_US
dc.description.abstractAn experimental technique is developed to simultaneously measure both temporal and spatial coherences of a light source by altering a standard Michelson interferometer, which has been primarily used for measuring temporal coherence only. Instead of using simple plane mirrors, two retroreflectors and their longitudinal and lateral movements are utilized to incorporate spatial coherence measurement using this modified Michelson interferometer. In general, one uses Young’s double slit interferometer to measure spatial coherence. However, this modified interferometer can be used as an optical setup kept at room temperature outside a cryostat to measure the spatiotemporal coherence of a light source placed at cryogenic temperatures. This avoids the added complexities of modulation of interference fringe patterns due to single slit diffraction as well. The process of mixing of spatial and temporal parts of coherences is intrinsic to existing methods for dual measurements. We addressed these issues of spatiotemporal mixing, and we introduced a method of “temporal filtering” in spatial coherence measurements. We also developed a “curve overlap” method that is used to extend the range of the experimental setup during temporal coherence measurements without compromising the precision. Together, these methods provide major advantages over plane mirror based standard interferometric systems for dual measurements in avoiding systematic errors, which lead to inaccuracies, especially for light sources with low coherences.en_US
dc.language.isoenen_US
dc.publisherAIP Publishingen_US
dc.subjectPhysicsen_US
dc.subject2021-OCT-WEEK3en_US
dc.subjectTOC-OCT-2021en_US
dc.subject2021en_US
dc.titleDual measurements of temporal and spatial coherence of light in a single experimental setup using a modified Michelson interferometeren_US
dc.typeArticleen_US
dc.contributor.departmentDept. of Physicsen_US
dc.identifier.sourcetitleReview of Scientific Instrumentsen_US
dc.publication.originofpublisherForeignen_US
Appears in Collections:JOURNAL ARTICLES

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.