Please use this identifier to cite or link to this item:
http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/7270
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | CMS Collaboration | en_US |
dc.contributor.author | Tumasyan, A. | en_US |
dc.contributor.author | ALPANA, A. | en_US |
dc.contributor.author | DUBE, SOURABH | en_US |
dc.contributor.author | KANSAL, B. | en_US |
dc.contributor.author | LAHA,A. | en_US |
dc.contributor.author | PANDEY, S. | en_US |
dc.contributor.author | RANE, A. | en_US |
dc.contributor.author | RASTOGI, A. | en_US |
dc.contributor.author | SHARMA, SEEMA et al. | en_US |
dc.date.accessioned | 2022-07-22T10:55:47Z | |
dc.date.available | 2022-07-22T10:55:47Z | |
dc.date.issued | 2022-08 | en_US |
dc.identifier.citation | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1037, 166795. | en_US |
dc.identifier.issn | 0168-9002 | en_US |
dc.identifier.issn | 1872-9576 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.nima.2022.166795 | en_US |
dc.identifier.uri | http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/7270 | |
dc.description.abstract | The strategies for and the performance of the CMS silicon tracking system alignment during the 2015–2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier B.V. | en_US |
dc.subject | CMS | en_US |
dc.subject | Detector | en_US |
dc.subject | Alignment | en_US |
dc.subject | Tracker | en_US |
dc.subject | Legacy reprocessing | en_US |
dc.subject | MillePede-II | en_US |
dc.subject | HipPy | en_US |
dc.subject | 2022-JUL-WEEK2 | en_US |
dc.subject | TOC-JUL-2022 | en_US |
dc.subject | 2022 | en_US |
dc.title | Strategies and performance of the CMS silicon tracker alignment during LHC Run 2 | en_US |
dc.type | Article | en_US |
dc.contributor.department | Dept. of Physics | en_US |
dc.identifier.sourcetitle | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_US |
dc.publication.originofpublisher | Foreign | en_US |
Appears in Collections: | JOURNAL ARTICLES |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.