dc.contributor.author |
Chatrchyan, S. |
en_US |
dc.contributor.author |
HEGDE, V. |
en_US |
dc.contributor.author |
KOTHEKAR, K. |
en_US |
dc.contributor.author |
PANDEY, S. |
en_US |
dc.contributor.author |
SHARMA, SEEMA et al. |
en_US |
dc.date.accessioned |
2019-09-11T05:04:52Z |
|
dc.date.available |
2019-09-11T05:04:52Z |
|
dc.date.issued |
2018-01 |
en_US |
dc.identifier.citation |
Journal of Instrumentation, 13, P01002. |
en_US |
dc.identifier.issn |
1748-0221 |
en_US |
dc.identifier.uri |
http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/4045 |
|
dc.identifier.uri |
https://doi.org/10.1088/1748-0221/13/01/P01002 |
en_US |
dc.description.abstract |
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillators, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
IOP Publishing |
en_US |
dc.subject |
Brightness |
en_US |
dc.subject |
Uniformity measurements |
en_US |
dc.subject |
Plastic scintillator |
en_US |
dc.subject |
CERN H2 test beam |
en_US |
dc.subject |
2018 |
en_US |
dc.title |
Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam |
en_US |
dc.type |
Article |
en_US |
dc.contributor.department |
Dept. of Physics |
en_US |
dc.identifier.sourcetitle |
Journal of Instrumentation |
en_US |
dc.publication.originofpublisher |
Foreign |