Digital Repository

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Show simple item record

dc.contributor.author CMS Collaboration en_US
dc.contributor.author Sirunyan, A. M. en_US
dc.contributor.author CHAUHAN, S. en_US
dc.contributor.author DUBE, SOURABH en_US
dc.contributor.author HEGDE, V. en_US
dc.contributor.author KANSAL, B. en_US
dc.contributor.author KAPOOR, A. en_US
dc.contributor.author KOTHEKAR, K. en_US
dc.contributor.author PANDEY, S. en_US
dc.contributor.author RANE, A. en_US
dc.contributor.author RASTOGI, A. en_US
dc.contributor.author SHARMA, SEEMA et al. en_US
dc.date.accessioned 2020-07-24T05:59:04Z
dc.date.available 2020-07-24T05:59:04Z
dc.date.issued 2020-06 en_US
dc.identifier.citation Journal of Instrumentation, 15(6). en_US
dc.identifier.issn 1748-0221 en_US
dc.identifier.uri http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/4895
dc.identifier.uri https://doi.org/10.1088/1748-0221/15/06/P06009 en_US
dc.description.abstract Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate. en_US
dc.language.iso en en_US
dc.publisher IOP Publishing en_US
dc.subject CMS en_US
dc.subject Physics en_US
dc.subject TOC-JUL-2020 en_US
dc.subject 2020 en_US
dc.subject 2020-JUL-WEEK4 en_US
dc.title Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter en_US
dc.type Article en_US
dc.contributor.department Dept. of Physics en_US
dc.identifier.sourcetitle Journal of Instrumentation en_US
dc.publication.originofpublisher Foreign en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account