Digital Repository

Comparison of post-Newtonian templates for extreme mass ratio inspirals

Show simple item record

dc.contributor.author Varma, Vijay en_US
dc.contributor.author Fujita, Ryuichi en_US
dc.contributor.author CHOUDHARY, ASHOK en_US
dc.contributor.author Iyer, Bala R. en_US
dc.date.accessioned 2020-10-19T08:59:38Z
dc.date.available 2020-10-19T08:59:38Z
dc.date.issued 2013-07 en_US
dc.identifier.citation Physical Review D, 88(2). en_US
dc.identifier.issn 1550-7998 en_US
dc.identifier.issn 1550-2368 en_US
dc.identifier.uri http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5183
dc.identifier.uri https://doi.org/10.1103/PhysRevD.88.024038 en_US
dc.description.abstract Extreme mass ratio inspirals (EMRIs), the inspirals of compact objects into supermassive black holes, are important gravitational wave sources for the Laser Interferometer Space Antenna (LISA). We study the performance of various post-Newtonian (PN) template families relative to the waveforms that are high-precision numerical solutions of the Teukolsky equation in the context of EMRI parameter estimation with LISA. Expressions for the time-domain waveforms TaylorT1, TaylorT2, TaylorT3, TaylorT4 and TaylorEt are derived up to 22 PN order, i.e. O(v44) (v is the characteristic velocity of the binary) beyond the Newtonian term, for a test particle in a circular orbit around a Schwarzschild black hole. The phase difference between the above 22 PN waveform families and numerical waveforms are evaluated during two-year inspirals for two prototypical EMRI systems with mass ratios 10 − 4 and 10 −5. We find that the dephases (in radians) for TaylorT1 and TaylorT2, respectively, are about 10−9 (10 − 2) and 10 −9 (10−3) for mass ratio 10 −4 (10−5). This suggests that using 22 PN TaylorT1 or TaylorT2 waveforms for parameter estimation of EMRIs will result in accuracies comparable to numerical waveform accuracy for most of the LISA parameter space. On the other hand, from the dephase results, we find that TaylorT3, TaylorT4 and TaylorEt fare relatively poorly as one approaches the last stable orbit. This implies that, as for comparable mass binaries using the 3.5 PN phase of waveforms, the 22 PN TaylorT3 and TaylorEt approximants do not perform well enough for the EMRIs. The reason underlying the poor performance of TaylorT3, TaylorT4 and TaylorEt relative to TaylorT1 and TaylorT2 is finally examined. en_US
dc.language.iso en en_US
dc.publisher American Physical Society en_US
dc.subject Evaluate Homogeneous Solutions en_US
dc.subject Gravitational-Waves en_US
dc.subject Numerical-Methods en_US
dc.subject Black-Holes en_US
dc.subject Radiation en_US
dc.subject 2013 en_US
dc.title Comparison of post-Newtonian templates for extreme mass ratio inspirals en_US
dc.type Article en_US
dc.contributor.department Dept. of Physics en_US
dc.identifier.sourcetitle Physical Review D en_US
dc.publication.originofpublisher Foreign en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account