Digital Repository

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

Show simple item record

dc.contributor.author CMS Collaboration en_US
dc.contributor.author Sirunyan, A. M. en_US
dc.contributor.author DUBE, SOURABH en_US
dc.contributor.author KANSAL, B. en_US
dc.contributor.author KAPOOR, A. en_US
dc.contributor.author KOTHEKAR, K. en_US
dc.contributor.author PANDEY, S. en_US
dc.contributor.author RANE, A. en_US
dc.contributor.author RASTOGI, A. en_US
dc.contributor.author SHARMA, SEEMA et al. en_US
dc.date.accessioned 2020-10-29T05:34:01Z
dc.date.available 2020-10-29T05:34:01Z
dc.date.issued 2020-10 en_US
dc.identifier.citation Journal of Instrumentation, 15(10). en_US
dc.identifier.issn 1748-0221 en_US
dc.identifier.uri http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5334
dc.identifier.uri https://doi.org/10.1088/1748-0221/15/10/P10002 en_US
dc.description.abstract A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the contribution to the signal of the increased number of out-of-time interactions per beam crossing following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (2015–2018) demonstrate a substantial improvement in the energy resolution of the calorimeter over a range of energies extending from a few GeV to several tens of GeV. en_US
dc.language.iso en en_US
dc.publisher IOP Publishing en_US
dc.subject Large detector-systems performance en_US
dc.subject Pattern recognition en_US
dc.subject Cluster finding en_US
dc.subject Calibration and fitting methods en_US
dc.subject 2020 en_US
dc.subject 2020-OCT-WEEK4 en_US
dc.subject TOC-OCT-2020 en_US
dc.title Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions en_US
dc.type Article en_US
dc.contributor.department Dept. of Physics en_US
dc.identifier.sourcetitle Journal of Instrumentation en_US
dc.publication.originofpublisher Foreign en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account