Digital Repository

Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics

Show simple item record

dc.contributor.author Chatrchyan, S. en_US
dc.contributor.author HEGDE, V. en_US
dc.contributor.author KOTHEKAR, K. en_US
dc.contributor.author PANDEY, S. en_US
dc.contributor.author SHARMA, SEEMA et al. en_US
dc.date.accessioned 2020-12-16T11:01:20Z
dc.date.available 2020-12-16T11:01:20Z
dc.date.issued 2017-03 en_US
dc.identifier.citation Journal of Instrumentation, 12. en_US
dc.identifier.issn 1748-0221 en_US
dc.identifier.uri http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/5442
dc.identifier.uri https://doi.org/10.1088/1748-0221/12/12/P12034 en_US
dc.description.abstract The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a 60Co radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Here we describe the instrumentation details and the operational experiences related to the sourcing test. en_US
dc.language.iso en en_US
dc.publisher IOP Publishing en_US
dc.subject Detector alignment and calibration methods (lasers, sources, particle-beams) en_US
dc.subject Calorimeter methods en_US
dc.subject Calorimeters en_US
dc.subject 2017 en_US
dc.title Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics en_US
dc.type Article en_US
dc.contributor.department Dept. of Physics en_US
dc.identifier.sourcetitle Journal of Instrumentation en_US
dc.publication.originofpublisher Foreign en_US