Digital Repository

An analytical model for electronic noise in a cryogenic bolometer detector readout circuit

Show simple item record

dc.contributor.author Vatsa, V. en_US
dc.contributor.author Raza, V. en_US
dc.contributor.author Mazumdar, A. en_US
dc.contributor.author Pose, M. S. en_US
dc.contributor.author Mallikarjunachary, S. en_US
dc.contributor.author Nanel, V. en_US
dc.contributor.author Pillay, R. G. en_US
dc.contributor.author RAMAKRISHNAN, S. en_US
dc.contributor.author Shrivastava, A. en_US
dc.date.accessioned 2023-01-31T09:21:46Z
dc.date.available 2023-01-31T09:21:46Z
dc.date.issued 2022-11 en_US
dc.identifier.citation Journal of Instrumentation, 17, T11013. en_US
dc.identifier.issn 1748-0221 en_US
dc.identifier.uri https://doi.org/10.1088/1748-0221/17/11/T11013 en_US
dc.identifier.uri http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/7578
dc.description.abstract This paper presents an analytical model to quantify the measured noise in a cryogenic bolometer readout circuit. The model includes the contributions from the bias resistors and sensor resistors, voltage and current noise of amplifier, and cable capacitance. The model parameters are empirically estimated using frequency domain analysis of the measured noise data of indigenously developed Neutron Transmutation Doped (NTD) Ge sensors. The model is shown to describe noise data for NTD Ge sensors over a wide range of resistances corresponding to temperatures in the range 20–70 mK. Relative contributions of different components are discussed and it is shown that the contribution to the overall noise from the differential amplifier at 300 K is the dominant source. It is observed that the amplifier flicker noise is significantly lower than that specified in the amplifier datasheet. The present study also indicates that a desirable value of resistance of NTD sensor (RNTD) from noise considerations is ≲ 1 GΩ at ∼ 20 mK. en_US
dc.language.iso en en_US
dc.publisher IOP Publishing en_US
dc.subject Cryogenic detectors en_US
dc.subject Front-end electronics for detector readout en_US
dc.subject Double-beta decay detectors en_US
dc.subject 2022 en_US
dc.title An analytical model for electronic noise in a cryogenic bolometer detector readout circuit en_US
dc.type Article en_US
dc.contributor.department Dept. of Physics en_US
dc.identifier.sourcetitle Journal of Instrumentation en_US
dc.publication.originofpublisher Foreign en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account