Digital Repository

Rectification of kinematic parameters of dissociative ionization derived from ion momentum spectra

Show simple item record

dc.contributor.author SRIVASTAV, AKASH en_US
dc.contributor.author VISHNU, P. en_US
dc.contributor.author BAPAT, BHAS en_US
dc.date.accessioned 2025-04-15T06:50:31Z
dc.date.available 2025-04-15T06:50:31Z
dc.date.issued 2025-02 en_US
dc.identifier.citation International Journal of Mass Spectrometry, 508, 117392. en_US
dc.identifier.issn 1387-3806 en_US
dc.identifier.issn 1873-2798 en_US
dc.identifier.uri https://doi.org/10.1016/j.ijms.2024.117392 en_US
dc.identifier.uri http://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/9494
dc.description.abstract Ion momentum spectrometers, which are commonly used devices for studying molecular dissociation, are lossy devices in that not all charged fragments are assuredly detected. Combined with the fact that neutrals are always undetected, this can result in a mixing of distinct dissociation channels. A dissociation event with all charged fragments may mimic an event where at least one fragment is neutral. As a result, an analysis of the dissociation channels identified using an ion pair coincidence map may result in misleading interpretations, especially when analyzing channels with both charged and neutral fragments. In this study, we present a method to rectify the distributions of kinematic parameters for such cases. The rectification method is discussed in the context of the (O+, C+, O) breakup channel of the CO22+ molecular ion. The distribution of the kinematic parameters after rectification exhibit stark differences from the raw distributions, emphasizing the need for rectification. A comparison of the rectified data with cases in the literature where such losses are estimated to be negligible, underline the efficacy of the method. en_US
dc.language.iso en en_US
dc.publisher Elsevier B.V. en_US
dc.subject Molecular dissociation en_US
dc.subject Molecular ions en_US
dc.subject Coincidence momentum imaging en_US
dc.subject Momentum spectrometer en_US
dc.subject Losses en_US
dc.subject Incomplete Coulombic dissociation en_US
dc.subject 2025 en_US
dc.title Rectification of kinematic parameters of dissociative ionization derived from ion momentum spectra en_US
dc.type Article en_US
dc.contributor.department Dept. of Physics en_US
dc.identifier.sourcetitle International Journal of Mass Spectrometry en_US
dc.publication.originofpublisher Foreign en_US